Silicone Rubber Insulated Thermocouple & Extension Wire (SIL-SIL)
1 Calibration: K, J, T, E, N, R, S
2 Conductor insulation material: Silicone rubber
3 Inner shield material: SSB
4 Jacket insulation material: Silicone rubber
5 Outer shield material: SSB
6 Wire size: 30AWG, 26AWG, 24AWG, 20AWG, 16AWG
7 'S' means 'Stranded'; 'Blank' means 'Solid'
Order Code
Type |
Wire |
Conductor |
Calibration |
|||
Type J |
Type K |
Type T |
Type E |
|||
THERMOCOUPLE |
16 |
Solid |
J-SIL-SIL-16 |
K-SIL-SIL-16 |
T-SIL-SIL-16 |
E-SIL-SIL-16 |
20 |
Solid |
J-SIL-SIL-20 |
K-SIL-SIL-20 |
T-SIL-SIL-20 |
E-SIL-SIL-20 |
|
20 7/28 |
Stranded |
J-SIL-SIL-20S |
K-SIL-SIL-20S |
T-SIL-SIL-20S |
E-SIL-SIL-20S |
|
22 7/30 |
Stranded |
J-SIL-SIL-22S |
K-SIL-SIL-22S |
T-SIL-SIL-22S |
E-SIL-SIL-22S |
|
24 |
Solid |
J-SIL-SIL-24 |
K-SIL-SIL-24 |
T-SIL-SIL-24 |
E-SIL-SIL-24 |
|
24 7/32 |
Stranded |
J-SIL-SIL-24S |
K-SIL-SIL-24S |
T-SIL-SIL-24S |
E-SIL-SIL-24S |
|
30 |
Solid |
J-SIL-SIL-30 |
K-SIL-SIL-30 |
T-SIL-SIL-30 |
E-SIL-SIL-30 |
|
EXTENSION |
16 |
Solid |
JX-SIL-SIL-16 |
KX-SIL-SIL-16 |
TX-SIL-SIL-16 |
EX-SIL-SIL-16 |
20 |
Solid |
JX-SIL-SIL-20 |
KX-SIL-SIL-20 |
TX-SIL-SIL-20 |
EX-SIL-SIL-20 |
|
20 7/28 |
Stranded |
JX-SIL-SIL-20S |
KX-SIL-SIL-20S |
TX-SIL-SIL-20S |
EX-SIL-SIL-20S |
|
24 |
Solid |
JX-SIL-SIL-24 |
KX-SIL-SIL-24 |
TX-SIL-SIL-24 |
EX-SIL-SIL-24 |
|
24 7/32 |
Stranded |
JX-SIL-SIL-24S |
KX-SIL-SIL-24S |
TX-SIL-SIL-24S |
EX-SIL-SIL-24S |
All above thermocouple and extension wire can be finished with a inner shield (Stainless steel-SSB, Tinned plated copper-TCB, Iron plated zinc-IZB and so on). If you need the wire with a inner shield, please add "SSB, TCB or IZB" to the order code, such as "JX-SIL-SSB-SIL-20S", it means Type JX, 20AWG, Stranded, Conductor insulation: Silicone rubber, Inner shield: Stainless steel, Jacket insulation: Silicone rubber
Outer shield
All above thermocouple and extension wire also can be finished with a metal outer shield to give added protection from abrasion and mechanical damage. If you need the wire with a outer shield, please add "SSB, TCB or IZB" to the order code, such as "JX-SIL-SIL-SSB-20S", it means Type JX, 20AWG, Stranded, Conductor insulation: Silicone rubber, Jacket insulation: Silicone rubber, Outer shield: Stainless steel
|
|
|
Model: KX-SIL-SIL-24S | Model: JX-SIL-SIL-24S | Model: KX-SIL-SIL-24S |
Thermocouple Type |
ANSI Color Code |
Initial Calibration Tolerances |
||||
Wire Alloys |
Calibration |
+/- |
Jacket |
Temperature Range |
Standard |
Special |
Iron(+) vs. |
J |
White/Red |
Brown |
0°C to +285°C |
±2.2°C |
±1.1°C |
CHROMEL(+) vs. |
K |
Yellow/Red |
Brown |
-200°C to -110°C |
± 2% |
±1.1°C |
Copper(+) vs. |
T |
Blue/Red |
Brown |
-200°C to -65°C |
± 1.5% |
± .8% |
CHROMEL(+) vs. |
E |
Purple/Red |
Brown |
-200°C to -170°C |
± 1% |
±1°C |
Extension Type |
ANSI Color Code |
Initial Calibration Tolerances |
||||
Wire Alloys |
Calibration |
+/- |
Jacket |
Temperature Range |
Standard |
Special |
Iron(+)vs. Constantan(-) |
JX |
White/Red |
Black |
0°C to +200°C |
±2.2°C |
±1.1°C |
CHROMEL(+) vs. ALUMEL(-) |
KX |
Yellow/Red |
Yellow |
0°C to +200°C |
±2.2°C |
±1.1°C |
Copper(+) vs. Constantan(-) |
TX |
Blue/Red |
Blue |
-60°C to +100°C |
±1.1°C |
± .5°C |
CHROMEL(+) vs. Constantan(-) |
EX |
Purple/Red |
Purple |
0°C to +200°C |
±1.7°C |
±1.1°C |
Characteristics |
Insulation |
Jacket |
Abrasion Resistance |
Fair |
Fair |
Cut Through Resistance |
Good |
Good |
Moisture Resistance |
Good |
Good |
Solder Iron Resistance |
Poor |
Poor |
Service Temperature |
200℃ continuous 260℃ single |
200℃ continuous 260℃ single |
Flame Test |
Self-extinguishing |
Self-extinguishing |